TECHNICAL DATA

8

101

OPTIWAVE 5200 C/F

www.krohne.com

07/2013 - 4001904902 - HB OPTIWAVE 5200 R02 en

8.2 Technical data

INFORMATION!

The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local sales office.

Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Download Center).

Measuring system

Measuring principle

2-wire loop-powered level transmitter; X-band (10 GHz) FMCW radar

Application range

Level measurement of liquids, pastes and slurries

Primary measured value

Distance and reflection

Secondary measured value

Level, volume, mass and flow rate

Design

Construction

The measurement system consists of a measuring sensor (antenna) and a signal

converter

Options

Integrated LCD display (-20..+60°C / -4…+140°F); if the ambient temperature is not

in these limits, the display switches off automatically

High-temperature (HT) extension (if the process connection temperature is more

than +150°C / +302°F - Metallic Horn antenna only)

Straight antenna extensions

Max. extension length, PTFE Wave Horn antenna: 300 mm / 11.8¨;

Max. extension length, Metallic Horn antenna: 1000 mm / 39.4¨

"S" antenna extension

- only for DN150/6¨ and DN200/8¨ Metallic Horn antenna options

"L" (right angle) antenna extension

- only for DN150/6¨ and DN200/8¨ Metallic Horn antenna options

Antenna purging system

- only for DN150/6¨ and DN200/8¨ Metallic Horn antenna options

Heating / cooling system (with or without the antenna purging system)

- only for DN150/6¨ and DN200/8¨ Metallic Horn antenna options

Signal cable for remote housing version (refer to cable properties in "Electrical

connection: Remote device version")

Weather protection - for the compact version or the antenna housing (remote

version). It cannot be ordered after delivery of the device.

Max. measuring range

PTFE and PP Wave Horn antennas:

PTFE and PP Wave Horn antennas:

PTFE and PP Wave Horn antennas:

PTFE and PP Wave Horn antennas:

20 m / 65.6 ft

DN80 / DN100 Metallic Horn antennas (installation only in stilling wells):

DN80 / DN100 Metallic Horn antennas (installation only in stilling wells):

DN80 / DN100 Metallic Horn antennas (installation only in stilling wells):

DN80 / DN100 Metallic Horn antennas (installation only in stilling wells):

10 m / 32.8 ft

DN150 / DN200 Metallic Horn antennas:

DN150 / DN200 Metallic Horn antennas:

DN150 / DN200 Metallic Horn antennas:

DN150 / DN200 Metallic Horn antennas:

30 m / 98.4 ft

Wave Guide antenna:

Wave Guide antenna:

Wave Guide antenna:

Wave Guide antenna:

6 m / 19.7 ft

Also depends on the dielectric constant of the product and the installation type.

Refer also to "Antenna selection".

Min. tank height

1 m / 3.3 ft

Top dead zone

Minimum value: Antenna length + antennna extension length + 100 mm / 3.9¨