Specifications
108
GP-4503T: D-Sub 9 pin socket connector via an RS-485, PROFIBUS, or MPI cable.
NOTE:
*1
You can supply power to the Siemens PROFIBUS connector only. You
cannot supply power to the device/PLC.
*2
The SG and FG terminals are isolated.
Interfit bracket is #4-40 (UNC).
Recommendations:
z
Cable Connector: XM2A-0901 manufactured by OMRON Corporation.
z
Cable Cover: XM2S-0913 manufactured by OMRON Corporation.
z
Jack Screw (#4-40 UNC): XM2Z-0073 manufactured by OMRON Corporation.
Pin Connection
Pin
No.
RS-485 (isolation)
Signal Name
Direction
Meaning
1
NC
-
no connection
2
NC
-
no connection
3
Line A
Input/Output
Data A (+)
4
RS(RTS)
Output
Request to Send
5
SG
-
Signal Ground
6
VCC
-
+5V±5% External Output
*1
7
NC
-
no connection
8
Line B
Input/Output
Data B (-)
9
NC
-
no connection
Shell
FG
–
Frame Ground
*2
(Not
connected with SG)
CAUTION
LOSS OF COMMUNICATION
z
All connections to the communication ports must not put excessive stress on the
ports.
z
Securely attach communication cables to the panel wall or cabinet.
z
Use only D-Sub 9 pin cables with a locking tab in good condition.
Failure to follow these instructions can result in injury or equipment damage.
6
9
1
5
(GP unit side)
- GP4500R - 10.4 Standard HMIs with Rear Mounting Options" GP4400R - 7.5 Standard HMI with Rear Mounting Options" GP4300R - 5.7 Standard HMI with Rear Mount" GP4300M - 5.7 Modular HMI" GP4200M - 3.5 Modular HMI" GP4500 - 10.4 W Model HMI" GP4400 - 7.0 W Model HMI" GP4300 - 5.7 W Model HMI" GP4200 - 3.5 W Model HMI" GP4600 - 12.1 Standard HMIs" GP4500 - 10.4 Standard HMIs" GP4400 - 7.5 Standard HMI" GP4300 - 5.7 Standard HMI" GP4200 - 3.5 Standard HMIs"