Type 6 Carrier Board Design Guide

Page 80

Figure 5-8: Basic Module Heatspreader Footprint

All dimensions are in mm. X-Y tolerances shall be ± 0.3mm [±0.012"].

The interior holes at coordinates (40, 40) and (80, 40) are tapped through holes with a

M2.5 thread. The interior holes do not receive standoffs. These holes may be sealed on

the module side by an adhesive backed foil, or they may be blind tapped holes with a

minimum thread depth of 2.5 mm. They are intended to allow additional attachment points

to the heatspreader from outside the module.