beautypg.com

Conquest m2 interface, Status led function description, Manual trigger – Teledyne LeCroy Conquest User Manual - Users Manual User Manual

Page 16

background image

Introduction

6

Conquest M2 Interface

Status LED Function Description

PWR When illuminated indicates that Analyzer is powered up.

TRG

When illuminated indicates that the Analyzer has triggered.

Manual Trigger

Manual trigger is activated by a push button switch on the front panel.

External Signals (Ext. Out, Ext. Trig In, and Ext. Clk)

The Conquest M2 Analyzer can output a unique 8-bit, user-defined CMOS
level when triggered. You can use these outputs for activating external
devices, such as other types of test equipment, when certain events are
detected in USB data capture.

Additionally, the Conquest M2 Analyzer provides you with an External Trigger
Input that allows you to trigger the Analyzer from externally generated
sources. Trigger input can be masked or programmed to respond to a 1 or 0
level or a rising or falling edge. For setting the external trigger input options,
see page 51.

Conquest M2 offers a number of internally generated pre-defined low
frequency clock settings, however you can apply an external clock to the
External Clock Input. Supported frequencies are in ranges of 400KHz - 8MHz
for High Speed and 1KHz-100KHz, 400KHz - 8MHz for Full/Low speed.