beautypg.com

Teledyne LeCroy PXA125 User Manual

Page 188

background image

User Manual PXA125

Programming Reference 4-70

OFF or 0 will turn off STAR triggers

Parameter type

Discrete

TRIGger:STAR?

Response and default
The PXA125 will return 1 if star lines are active, or 0 if star lines are disabled. Default value is 0.

TRIGger:TIMer

Purpose
This command will set the period for the internal trigger generator.

will set the timer of the internal trigger generator

Parameter type

Numeric

Parameter range

100e-3 to 5e6 in units of seconds

TRIGger:TIMer?

Response and default
The PXA125 will return the present internal trigger timer value. The returned value will be in standard
scientific format (for example: 10ms would be returned as 10E-3 – positive numbers are unsigned). Default
value is 1e3.

TRIGger:IMMediate

Purpose
This command will stimulate the PXA125 output once. This command will affect the PXA125 only after it will
be set to interrupted operation.

*TRG

Purpose
This common command has the same affect as the TRIG:IMM command.