User Manual PXA125

Programming Reference 4-47

1e-3 to 1000 in units of seconds

SWEep:TIME?

Response and default
The PXA125 will return the present sweep time value. The returned value will be in standard scientific format
(for example: 10ms would be returned as 10E-3 – positive numbers are unsigned). Default value is 1e-3.

SWEep:DIRection{UP|DOWN}

Purpose
This command will select the sweep direction up and down.

selects an up direction. The sample clock will sweep from start frequency set by the sclk parameter

to stop frequency set by the stop sclk parameter

selects the down direction. The sample clock will sweep from stop frequency set by the stop

sclk parameter to start frequency set by the sclk parameter

Parameter type

Discrete

SWEep:DIRection?

Response and default
The PXA125 will return UP, or DOWN depending on the present PXA125 setting. Default value is UP.

SWEep:SPACing{LINear|LOGarithmic}

Purpose
This command will select the sweep spacing from linear spacing and logarithmic spacing.

will select linear steps

will select logarithmic steps

Parameter type

Discrete

SWEep:SPACing?

Response and default
The PXA125 will return LIN, or LOG depending on the present PXA125 setting. Default value is LIN.

SWEep:TRIGger:MODE{CONTinuous|TRIGered|GATEd}

Purpose
This command will select one of the sweep modes.

CONTinuous will select continuous sweep modulation

TRIGered will select triggered sweep modulation

GATEd will select gated sweep modulation

Parameter type

Discrete

SWEep:TRIGger:MODE?