Programming Reference 4-66

ARM:SLOPe{POSitive|NEGative}

Purpose
This command will set the edge sensitivity of which the PXA125 will stop in arm mode. The stop and start
commands are applied at the rear-panel TRIG IN connector.

POSitive will set the positive edge

NEGative will set the negative edge

Parameter type

Discrete

ARM:SLOPe?

Response and default
The PXA125 will return POS, or NEG depending on the present setting. Default value is POS.

ARM:BREakpoint:POSition

Purpose
This command will program the breakpoint position for the arm function.

will set the breakpoint position

Parameter type

Numeric (integer only)

Parameter range

0 to “n” in units of waveform points, where “n” is the size of the active segment. The
breakpoint position can be programmed in increments of 4 points minimum.

ARM:BREakpoint:POSition?

Response and default
The PXA125 will return the present breakpoint value. Default value is 0.

INITiate:CONTinuous{OFF|ON|0|1}

Purpose
This command will set the output in continuous operation and interrupted operation. The trigger subsystem
commands will affect the PXA125 only after it will be set to interrupted operation.

ON or 1 will set the continuous mode

OFF or 0 will set the interrupted mode

Parameter type

Discrete

INITiate:CONTinuous?

Response to query version