IAI America ISPDACR-ESD User Manual
Page 93
85
12. Motor Replacement Procedures
12.3.2
ECON and SCON Controllers
(1) Open the position edit screen.
On the PC software screen, click , select a desired position number, and then click OK to display
the following screen.
(2) Compare the current value and the value achieved by positioning the actuator to the selected position
number.
Click this button to open the position edit screen.
Point number
[2] Click this button to
make a step movement.
[1] Select the position.
The current value is displayed.
This manual is related to the following products: