beautypg.com

Motor replacement procedures – IAI America ISPDACR-ESD User Manual

Page 71

background image

63

12. Motor Replacement Procedures

12. Motor Replacement Procedures

(Note) Motors in the ISD, ISDCR and ISPDCR series cannot be replaced by customers. Should you

require motor replacement on any of these actuators, please consult IAI.

12.1 Replacing the Motor of the Standard Type ISDA/ISPDA/ISDACR/ISPDACR Series

* All photographs are those of the ISDACR.

“What you need for replacement”

x New motor (with a coupling on the motor shaft,

as shown in the photograph on the right)

Caution: Never remove this coupling.

x Allen

wrench

set

x Phillips

screwdriver

x Scale

[Steps]
(1) Removing the Motor Cover

Remove the two bolts that secure the motor cover.

Type

Nominal

diameter

Length

(mm)

Quantity

IS(P)DA(CR)-S

M4 12 2

IS(P)DA(CR)-M

M5 20 2

IS(P)DA(CR)-L

M5 25 2

Hold the cover and pull it backward to remove.