IAI America ISPDACR-ESD User Manual
Page 33

25
6SHFL¿FDWLRQ
[Cleanroom types ISPDCR-W/ISDACR-W/ISPDACR-W]
Allowable load moments and allowable overhung load lengths of each actuator are shown below. Make
sure the applicable allowable values are not exceeded.
Allowable load moment (Nm)
Ma Mb Mc
112.7 N-m (11.5 kgf-m)
161.7 N-m (16.5 kgf-m)
356.7 N-m (36.4 kgf-m)
Allowable overhung load (L)
Ma Direction
Mb Direction
Mc Direction
800 or less
800 or less
800 or less
The allowable overhangs assume that the center of gravity of the installed object is located at a position
one half the overhang length.
Mb or Mc direction
Direction of moment
Direction of allowable overhang
Ma direction