81
12. Motor Replacement Procedures
12.3 How to Set the Home Preset and Home Return Offset
Correct the position deviation by changing the parameter for home preset in the case of a XSEL or SSEL
controller, or by changing the parameter for home return offset in the case of a SCON parameter. How to
set these parameters is explained below.
12.3.1
XSEL and SSEL Controllers
(1) Open the position edit screen.
On the PC software screen, click , select a desired position number, and then click OK to display
the following screen.
(2) Compare the current value and the value achieved by positioning the actuator to the selected position
number, and check the amount of deviation.
The current value is displayed.
Position number
[2] Click MV.
[1] Select the position to
move the actuator to.
Click this button to open the position edit screen.