Profibus-dp – Fairbanks FB2550 DAT SERIES DRIVER ACCESS TERMINAL User Manual
Page 96

Section 4: Input/ Output
2/2013
96
51303 Rev. 1
5.8.5. PROFIBUS-DP
PROFIBUS-DP
(
30922
) is one of the best-known
industrial Fieldbus protocols from Europe.
– It is an established standard, used in a wide
range of applications as a multi-application
communications link for industrial devices.
– The PROFIBUS-DP protocol was originally
developed by a committee founded by the
German government.
PROFIBUS-DP
utilizes a non-powered two-wire (RS-485) Network.
– A PROFIBUS-DP Network may have up to 126 nodes, transfering a
maximum of 244 bytes data per node/ per cycle.
– Baud (Communication) Rates are selectable, and overall end-to-end network
distance varies with speed.
– The maximum standard Baud Rate is 12Mbps, with a maximum distance of
100M (328ft),
and 1200M (3936 ft) at 93.75Kbps without repeaters.
–
PROFIBUS-DP
connects to a wide variety of field devices including the
following:
▪ Discrete and analog I/O Drives.
▪ Robots.
▪ HMI/MMI products.
▪ Pneumatic valves.
▪ Barcode readers.
▪ Weigh scales.
▪ Transducers.
▪ Flow measuring equipment.
PIN
SIGNAL
DESCRIPTION
3
B-Line
Positive RxxD/TxD, Rs485 level
4
RTS
Request to Send
5
GND
Ground (Isolated)
6
+5 Bus
Output
+5V termination power (Isolated,
short circuit protected)
8
A-Line
Negative RXD/TxD, RS485 level