Serial 20ma configuration (serial expansion board) – Fairbanks FB2550 DAT SERIES DRIVER ACCESS TERMINAL User Manual
Page 86

Section 4: Input/ Output
2/2013
86
51303 Rev. 1
5.5.3. SERIAL 20mA CONFIGURATION (SERIAL
EXPANSION BOARD)
1. Using an external keyboard, press
ALT +
HOME
. Select
LOGIN
.
2. Enter the Supervisor Password.
3. Select the
CONFIGURATION
MENU
.
4. Press
PAGE FORWARD
once.
5. Select
REMOTE DISPLAY
.
6. Touch the data box on the screen to the right
of
COM
PORT
,
selecting the desired COM
port.
7. Select the
DISPLAY MODE
button,
selecting the desired mode required from the
menu list.
– The menu choices are Continuous
Display
or Display on Print.
8. Touch the data box on the screen to the right
of
OUTPUT TYPE:,
then select the
desired type required from the menu list.
– The types are Gross Wt, Net Wt, or Ticket Number.
9. Touch the data box on the screen to the right of
OUTPUT SCALE:,
then select
the desired scale required from the menu list.
– The scales choices are All, Active or an individual scale.
– It is recommended to leave the settings for baud, parity, and etc. as shown in
the images in steps 3 and 4.
Do Not
touch the data check box on the screen to the left of Enable 20 mA Output.
– This turns on the 20 mA output located at
J1
, which resides on the Multi-Function
Board.
– This is not required for this Configuration
Setup
.
– If the check box is selected by Enabled
1605T Remote Display Traffic Light
Control
, the FB2550 DAT will control the
traffic light function.