background image

Section 3: Configuration Menu

2/2013

68

51303 Rev. 1

4.7. RS-485 CONFIGURATION

The RS-485 output is available from the RS-485 accessory (

30937

), or from the

Serial Expansion accessory

(

30921

).

Refer to Section 8.8.3. Method 1 – Pre-configured Output or Section

8.8.4. Method 2. – Customizing Output Data Strings.

– These sections describe how to configure the data string protocol for the

communications.

– The final step for the RS-485 configuration is to assign an ID for the RS-485

communications network.

– This address is a requirement for proper operation.

Follow these steps to configure the RS-485 ID.

1. Using an external keyboard, press

ALT +

HOME

. Select

LOGIN

.

2. Enter the Supervisor Password.

3. Select the

CONFIGURATION MENU

4. Press

PAGE FORWARD

once.

5. Select

CONFIGURE OUTPUTS

.

6. Touch the screen to select

Edit RS-485

ID

to edit or enter the RS-485 ID.

7. Touch the screen to the right of

RS-485 ID

to enter the RS-485 ID from the keyboard.
– The ID value may be configured from 1

to 32

.

– A

ZERO (0)

disables the ID.

8. Press the

SAVE CHANGES

button when

any changes are made, otherwise they will be
lost.