External keyboard – Fairbanks FB2550 DAT SERIES DRIVER ACCESS TERMINAL User Manual
Page 17
Section 2: Operations
2/2013
17
51303 Rev. 1
2.2. EXTERNAL KEYBOARD
KEY
FUNCTION
F1
This key is not operational in the weight processing screen.
F2
This key is not operational in the weight processing screen.
F3
Reprint Ticket. This key will permit the reprinting of a previously printed
ticket. This key will also function to pull up a list of items such as Loop,
Customer, or Product during the weighing process.
F4
This key is not operational in the weight processing screen.
F5
This key is not operational in the weight processing screen. This key, while
in the configuration menu, performs as a backup key to the previous screen.
ALT + F5
Power Off. This key
with the
ALT key
held down
turns the instrument off.
The power cord must be unplugged and plugged back in to power up the
instrument
ALT + Pause Break
This key with the
ALT key
held down will Zero the scale .
ALT + Zero
The
ALT key
held down plus pressing the Zero key on the keypad will Zero
the scale .
ALT + Scroll Lock
This key with the
ALT key
held down will toggle the Units.
ALT + Units
The
ALT key
held down plus pressing the Units key on the keypad will
toggle the scales units. .
PrtSc SysRq
Will initiate a print cycle.
ALT + Home
This key with the
ALT key
held down will open the Menu for the
Configuration Home.
ALT + Menu
The
ALT key
held down plus pressing the Menu key on the keypad will
open the Menu for the Configuration Home.
ESC
Clear or restart.
Ctrl + Shift + H
System Information
Ctrl + Shift + S
Displays Expansion modules installed.
Alphanumeric keys
Used to enter various data. i.e. – truck id’s, products, customers
Up Arrow
Navigate up.
Down Arrow
Navigate down.
Left Arrow
Navigate left.
Right Arrow
Navigate right.