20ma analog card, Isolated power supply, Catastrophic damage – Fairbanks FB2550 DAT SERIES DRIVER ACCESS TERMINAL User Manual
Page 87
Section 4: Input/ Output
2/2013
87
51303 Rev. 1
5.6. 20mA ANALOG CARD
The
4-20 MA ANALOG CARD (30919)
is a Passive Current Loop Device
with 16 Bit High Resolution Output.
4-20mA
Specifications
– 16 bit resolution +/- .01 integral linearity
Current Loop Voltage
Compliance
A
PASSIVE DEVICE
, as the 4-20 Analog Card is, does not supply
any current loop voltage.
Customer’s external source must furnish 7 to 40 VDC power (typical
voltage 24 VDC).
The negative (-) power of the supply MUST be isolated from chassis
ground
See important
CAUTION
box below.
A separate power supply must be furnished for each output.
Full Scale Setting
Time
– 8
msecs.
Output Impedance
– 25 Meg Ohms.
Alarm Current
– 3.5 to 24mA (underload/overload conditions), Offset at
25°C; +/- .1% of full scale. Offset drift; +/- 25 ppm of full
scale per degree Celsius.
Total Output Error
– (20mA) at 25°C: +/- .2% of full scale max.
Total Output Drift
– +/- 50 ppm of full scale per degree Celsius max.
C A U T I O N
Failure to have an
ISOLATED POWER SUPPLY
WILL CAUSE
CATASTROPHIC DAMAGE!
Above is an example of wiring two (2) passive
nodes with an external power supply.