Method 1, continued – Fairbanks FB2550 DAT SERIES DRIVER ACCESS TERMINAL User Manual
Page 55

Section 3: Configuration Menu
2/2013
55
51303 Rev. 1
4.4.3. METHOD 1, CONTINUED
13. Enter the
SETTINGS
menu to configure
the settings as required.
14. Touch the data field to the right of the
Mode legend and a list of items will appear 
from which a selection is made. 
 
 
 
MODE
–
This field determines how the
data is transmitted.
OFF
–
COM port is disabled.
CONTINUOUS
–
The COM port
transmits the data string continuously per 
every display update. 
DEMAND
–
The data string is
transmitted upon receiving the 
programmed poll character from a peripheral device. 
AUTO
–
The data string is transmitted upon the printing of a transaction.
NETWORK
(CONTINUOUS)
-
The data string is transmitted continuously
per every display update through the network connection.
NETWORK (AUTO)
-
The data string is transmitted upon pressing print and
the printing of a transaction will transmit the transaction through the network 
connection. 
 
15. Touch the data field to the right of the 
Baud legend and a list of items will appear 
from which a selection is made. 
16. Select the required
BAUD
rate from the
menu list. 
 
 