beautypg.com

Resetting to the axis factory defaults – Fairbanks FB2550 DAT SERIES DRIVER ACCESS TERMINAL User Manual

Page 107

background image

Section 5: Accessories

2/2013

107

51303 Rev. 1

6.3.4. RESETTING TO THE AXIS FACTORY DEFAULTS

Restoring the Factory Default Settings is used when the previous steps do not
resolve problems with the Camera Unit.

1. Disconnect the

POWER CABLE

from the Camera unit.


2. Remove the two (2) Torx screws,

holding the camera into place with a

T20 ALLEN KEY

.




3. Flip the camera over to reveal the

control components on the bottom.








4. Reconnect the Power Cable

.

– Wait

approximately

fifteen (15) seconds

until the NET and PWR

led lights are

orange.

5. Press and hold the

RESET

button for approximately thirty (30) seconds until

the

NET

led light flickers green, then release

RESET

button.

– Doing this resets the Factory Defaults.

6. Reassemble the Camera Unit and follow

STEPS 1-16

from SECTION 11.2. and

11.2.1.

to complete the programming process.

TORX Screws

RESET NET PWR
SWITCH LED LED