Appendix I: Fieldbus Interface Reference Data

2/2013

134

51303 Rev. 1

C. SOFTWARE SPECIFICATIONS, CONTINUED

INPUT

DATA FORMAT FROM GATEWAY, CONTINUED

STX

character 1

byte, (02h)

Command

word

0 2

bytes, (includes

scale

ID)

Command

word

1 2

bytes,

Command

word

2 2

bytes,

Setpoint

1

weight 6

characters,

Setpoint

2

weight 6

characters,

Tare

Weight

6

characters,

Display

Message

1

26

characters,

Display

Message

2

26

characters,

Display

Message

3

26

characters,

CRC

1

byte,

ETX

character 1

byte

(03h)


NOTE WEIGHT VALUES

sent over the serial channel will represent data in the

Fieldbus registers based on the settings of

bits 14

and

15

in

STATUS WORD 0

.

– If the data is set to be a 16 bit or 32 bit integer, then the integer value in the

register will be sent over the serial channel.

– If it is set to be 16 bit, the high order word will be ignored.
– If the data is set to be floating point, then the floating point value will be

multiplied by the scale factor and the integer portion of this resulting value will
be sent over the serial channel.

– In all cases if the resulting integer is greater than 999999, a value of

000000

will be sent over the Serial Channel.

– In all cases the scale must multiply the integer by the scale factor to determine

the actual weight.


 Serial data is transferred according to the RS232 specification between the

gateway and the FB2550 DAT. The communications parameters are listed below.

Baud 115,200

Data Bits

8

Parity None

Stop Bits

1