beautypg.com

E. status/command word bit usage – Fairbanks FB2550 DAT SERIES DRIVER ACCESS TERMINAL User Manual

Page 140

background image

Appendix I: Fieldbus Interface Reference Data

2/2013

140

51303 Rev. 1

E. STATUS/COMMAND WORD BIT USAGE

STATUS / COMMAND WORD 0

bit

Usage

0

Scale ID bits 0, 1, 2

1

Scale 1 = 001, Scale 2 = 010, Scale 3 = 011, Scale 4 = 100

2
3

motion

4

over capacity gross weight = scale capacity

5

within 2% capacity

6

Enable Tare

7

Disable Tare

8

lb units

9

kg units

10

ton units

11

tonne units

12
13
14

Weight conversion, text to numeric (bits 14 and 15)

15

01 = 32 bit floating point

10 = 32 bit integer

11 = 16 bit integer