1.4. GENERAL SERVICE POLICY

Prior to installation, always verify that the equipment satisfies the
customer's requirements as supplied, and as described in this manual.

If the equipment cannot satisfy the application and the application cannot
be modified to meet the design parameters of the equipment,

the

installation

should NOT be attempted.


It is the

customer/operator's responsibility

to ensure the equipment

provided by Fairbanks is operated within the parameters of the
equipment's specifications and protected from accidental or malicious
damage.

All load cells, load cell cables and interconnecting cables used to
connect all scale components shall be located

a minimum of thirty-six

(36”) inches distance away

from all single and multiple phase high

energy circuits and electric current carrying conductors.

– This includes digital weight indicators, junction boxes, sectional controllers,

and power supplies.

– This includes any peripheral devices, such as printers, remote displays, relay

boxes, remote terminals, card readers, and auxiliary data entry devices.

– Also included is the scale components themselves, such as 120 volt AC, 240

volt AC, 480 volt AC and electric supply of
higher voltage wiring runs and stations, AC
power transformers, overhead or buried cables,
electric distribution panels, electric motors,
florescent and high intensity lighting which
utilize ballast assemblies, electric heating
equipment, traffic light wiring and power, and
relay boxes.


All scale components, including digital weight
Instruments and peripheral devices are not
designed to operate on internal combustion
engine driven electric generators and other
similar equipment.