FieldbusmodulesPROFINETIO,

EtherNet/IPandMODBUSTCP

15.

FIELD BUS MODULES PROFINET IO,
ETHERNET/IP AND MODBUS TCP

15.1. PROFINET IO, EtherNet/IP and MODBUS TCP, IP20

- overview

Power Supply

LED Status Display

Field bus connection RJ45
(2 Port Ethernet Switch)

Functional earth

Connection for RIO slave

bus module –

see “10. Bus Module Rio

Slave (RIO/VA)”, page

46

Figure 48:

Overview of field bus modules PROFINET IO, EtherNet/IP, MODBUS TCP

15.1.1. Power supply IP20

The 4-pole plug-in connector for the power supply is configured as follows:

Electronics

Inputs

Valves /

Outputs

24 V DC (2)

valves /
outputs

24 V DC (4)

logic

GND (3)

logic

GND (1)

valves /
outputs

Pin 1

Pin 4

1

2 3 4

-

+

-

+

Pin

Valves /

Outputs

Logic

inputs

Figure 49:

Power supply configuration

Figure 50:

Cutaway POWER connection

Pin 2 of the power supply must be supplied with a 4 A medium time-lag fuse; Pin 4 with 1 A.

english