SMX System MultiMatrix Switcher • SMX Control Software

80

Enabling and disabling DHCP

Selecting the

Use DHCP

check box directs the SMX to ignore any entered IP addresses and

to obtain its IP address from a Dynamic Host Configuration Protocol (DHCP) server (if the
network is DHCP capable). Contact the local system administrator for information about
DHCP on your system.

ATTENTION: Selecting or deselecting this check box while the SMX is connected via

Ethernet can immediately disconnect your PC from the unit. It is recommended that you
connect via RS-232 or RS-422 to edit this field.

Setting the date

The

Date

field displays the current date in the Greenwich Mean Time (GMT) zone. If

necessary, adjust the date as follows:

1.

Click in the

Date

field. A date editing field appears, displaying the date in the format

(M)M/(D)D/YYYY

. Leading zeros are not used. The graphic cursor becomes a text

cursor in the date editing field.

2.

Edit the field as desired to set the proper date. Leading zeros are optional.

3.

Press the key on the keyboard or click in another field to exit the

Date

field.

4.

Click the

Take

button to make the date change take effect.

Setting the local time

The

Time (local)

field displays the current time in the local time zone. If necessary, click

the

Sync Time to PC

button to set the SMX to the internal time of your computer, or adjust

the time manually as follows:

1.

Click in the

Time (local)

field. A time editing field appears with the date in the format

HH:MM:SS (00:00:00 to 23:59:59)

. The graphic cursor becomes a text cursor in

the time editing field.

2.

Edit the field as desired to set the proper time. Remember to use 24-hour time. Leading
zeros are optional.

3.

Press the key or click in another field to exit the

Set Time

field.

4.

Click the

Take

button to make the time change take effect.

Sync time to PC button

Clicking the

Sync Time to PC

button causes the computer you are operating to send its

internal time to the SMX in a set time command.

Setting the offset from GMT

The

GMT

field displays the amount of time, in hours and minutes, that the local time varies

from the GMT international time reference. If necessary, adjust the offset as follows:

1.

Click in the

GMT

field. An offset editing field appears with the offset in the format

+HH:MM

(-12:00

to

+ 14:00)

. The graphic cursor becomes a text cursor in the set offset field.

2.

Edit the field as desired to set the proper offset. Leading zeros are optional. Some time
zones are on the half-hour (30 minutes).

3.

Press the key or click in another field to exit the

Set Offset

field.

4.

Click the

Take

button to make the offset change take effect.