SMX System MultiMatrix Switcher • Ethernet Control 106

Ethernet Control

This section describes Ethernet connection and Telnet communication to the SMX and
includes:

Ethernet Link

Subnetting — A Primer

Ethernet Link

The rear panel Ethernet connector on the SMX can be connected to an Ethernet
LAN or WAN. This connection makes SIS control of the SMX possible using a
computer connected to the same network.

Ethernet Connection

The Ethernet cable can be terminated as a straight-through cable or a crossover cable and
must be properly terminated for your application (see figure 63).

Crossover cable — Direct connection between the computer and the SMX.

Patch (straight) cable — Connection of the SMX switcher to an Ethernet LAN.

12345678

RJ-45 Connector

Insert

Twisted

Pair Wires

Pins:

Side View

Straight-through Cable

(for connection to a switch, hub, or router)

End 1

End 2

Pin Wire Color

Pin

Wire Color

1

white-orange

1

white-orange

2

orange

2

orange

3

white-green

3

white-green

4

blue

4

blue

5

white-blue

5

white-blue

6

green

6

green

7

white-brown

7

white-brown

8

brown

8

brown

Crossover Cable

(for direct connection to a PC)

End 1

End 2

Pin Wire Color

Pin Wire Color

1

white-orange

1

white-green

2

orange

2

green

3

white-green

3

white-orange

4

blue

4

blue

5

white-blue

5

white-blue

6

green

6

orange

7

white-brown

7

white-brown

8

brown

8

brown

Straight-through Cable

(for connection to a switch, hub, or router)

End 1

End 2

Pin Wire Color

Pin Wire Color

1

white-orange

1

white-orange

2

orange

2

orange

3

white-green

3

white-green

4

blue

4

blue

5

white-blue

5

white-blue

6

green

6

green

7

white-brown

7

white-brown

8

brown

8

brown

Crossover Cable

(for direct connection to a PC)

End 1

End 2

Pin Wire Color

Pin Wire Color

1

white-orange

1

white-green

2

orange

2

green

3

white-green

3

white-orange

4

blue

4

blue

5

white-blue

5

white-blue

6

green

6

orange

7

white-brown

7

white-brown

8

brown

8

brown

Figure 63.

RJ-45 Connector Pinout Tables

Default Address

To access the SMX via the Ethernet port, you need the SMX IP address. If the address has
been changed to an address comprised of words and characters, the actual numeric IP
address can be determined using the ping utility. If the address has not been changed, the
factory-specified default is 192.168.254.254.
Ping can also be used to test the Ethernet link to the SMX.