beautypg.com

Symbol definitions, Using the command/response table, For ip sis commands – Extron Electronics SMX System User Guide User Manual

Page 59

background image

SMX System MultiMatrix Switcher • SIS Configuration and Control

53

Using the Command/Response Table for IP SIS Commands

The

Command and Response Table

begins on page 42.

Symbol Definitions

X5!

= Specific port number

01

99

00

= reserved

The port number is represented as two
ASCII characters (for example, port 05
would be represented as 30 35 in hex).

X5@

= GMT offset

–12.0 - +14.0

Hours and minutes are removed from
GMT.

X5#

= On/Off status

0

= off or disabled

1

= on or enabled

X5$

= Unit name

Text string up to 24 characters (A-Z,
0-9, and "-").
Not case sensitive.

NOTE: The following characters are invalid or not recommended in the name:

~ , @ =

' [ ] { } < > ` " ; : | \ ?

and

space

The first character must be an alpha character, the last must not be a hyphen.

X5%

= Time and date (set and read)

MM/DD/YY•HH:MM:SS
MM

= month: 01 (January) through 12

(December)

DD

= day:

01

through

31

YY

= year:

00

through

99

HH

= hour:

00

through

23

MM

= minutes:

00

through

59

SS

= seconds:

00

through

59

X5^

= IP or gateway address

nnn.nnn.nnn.nnn

NOTE: Factory default IP/Gateway address: 192.168.254.254

X5&

= E-mail domain name

Standard name conventions apply; for
example, xxx.com.

NOTES:

The following characters are invalid or not recommended in the name:

~ , @ = '

[ ] { } < > ` " ; : | \ ?

and

space

The @ character is acceptable only as lead-in to the domain name (such as

@extron.com

)

X5*

= Hardware (MAC) address

xx-xx-xx-xx-xx-xx

X5(

= Default name

SMX-xx-xx-xx

X6)

= Subnet mask

nnn.nnn.nnn.nnn

NOTE: Leading zeros in each of the four fields are optional in setting values and

suppressed in returned values.