Extron Electronics SMX System User Guide User Manual
Page 52
![background image](/manuals/312382/52/background.png)
SMX System MultiMatrix Switcher • SIS Configuration and Control
46
Command
ASCII Command
(Host to switcher)
Response
(Switcher to host)
Additional Description
Query system status
S
X2$•X2$•X2$•X2%•X2^•X2^•X3#•X3$]
Query specific system status
nS
X2$
or
X2%
or
X2^
or
X3#]
Stsn*
X2$
or
X2%
or
X2^
or
X3#]
Verbose mode 2 or 3
Example:
S
Sts0* 3.31 4.98 24.22 +100.40 03305 03308 1 0
]
3.31 and 4.98 are power supply voltages; 24.22 is fan voltage,
100.40 (degrees F) is the temperature, 03305 is fan 1 rpm, 03308
is fan 2 rpm, 1 is primary power supply (OK).
Query switcher information
(general) per plane (16 actual
and 10 virtual) plus board
configuration
I
V
X@
0
X
X#
0
A
X@
0
X
X#
0
•
...
V
X@
15
X
X#
15
A
X@
15
X
X#
15
•
...
V
X@
25
X
X#
25
A
X@
25
X
X#
25
]
Example:
V16x16A16x16
•
V--X--A--X--
•
V--X--A--X--
•
V--X--A-
-X--
•
...
...
•
V--X--A--X--
]
NOTE:
The I response gives 26 parameters, the first 16 (V_x_A_x_) is plane information (planes 0-15), and the next
are virtual planes 1-10 (90-99).
Query model name
Example:
1I
Switcher description (short)
]
Inf01*Switcher description (short)
]
Verbose mode 2 or 3
Inf01*SMX
]
Query model description
Example:
2I
Switcher description (long)
]
Inf02*Switcher description (long)
]
Verbose mode 2 or 3
Inf02*System Multi Matrix
]
Query system-memory usage
3I
# of Bytes used out of # KBytes
]
Inf03*# of Bytes used out of # KBytes Verbose mode 2 or 3
Query user-memory usage
4I
# of Bytes used out of # KBytes
]
Inf04*# of Bytes used out of # KBytes Verbose mode 2 or 3
Query plane address per slot
E
STAT
}
X2@
(slot 1)
•X2@
(slot 2)
•
...
X2@
(slot 6/8/10)
]
Verbose mode 2 and 3
Stat
X2@
(slot 1)
•X2@
(slot 2)
•
...
X2@
(slot 6/8/10)
]
Example:
Stat*
5U frame, 10 slots
Slot 1
2
3
4 5 6 7
8 9 10
00
•
01
•
--
•
02
•
--
•
--
•
03
•
--
•
03
•
03
]
Slot 1 00 the board address installed in slot 1 is plane 00
Slot 2 01 the board address installed in slot 2 is plane 01
Slot 3 - - No board installed
NOTES:
X@
= Input number
01 - <maximum number of inputs>
00 = untied
X#
= Output number
01 - <maximum number of outputs>
X2@
= Plane number
00 - 15
90
- 99 = virtual plane
X2$
= Voltage + or – voltage
X2%
= Temperature
X2^
= Fan speed RPM
X3#
= Primary power supply
0 = not installed
1 = OK
2 = failed
X3$
= Secondary (redundant) power supply
0 = not installed
1 = OK
2 = failed