SMX System MultiMatrix Switcher • SIS Configuration and Control

39

X1^

= HDCP compliance

0

= no source connected

1

= source is HDCP compliant

2

= source is not HDCP compliant

X1&

= Executive mode

0

= enable (basic and admin)

1

= disabled front panel

2

= enabled (basic only)

X1*

= Reclocker rates for SDI/HD-SDI

boards

00

= auto detect (default)

01

= bypass reclocker

X1(

= Signal status

0

= no signal at the input

1

= signal at the input (H)

2

= signal at the input (V)

3

= signal at the input (HV/receive link

presence for fiber boards)

X2)

= Output connection status

0

= no active connection on A or B

1

= first (A) port connected and second

(B) port not connected

2

= first (A) port not connected and

second (B) port connected

3

= active connection on both A and B

X2!

= Version number

x.xx.xxxx

(the first 3 numbers is the

version number and the last 4 is the
build number)

X2@

= Plane addresses

00 – 15

= for 16 planes

90 – 99

= for virtual planes (10 planes)

X2$

= Voltage

Positive or negative voltage magnitude

X2%

= Temperature

In Degrees Fahrenheit

X2^

= Fan speed

In RPM

X2(

= Create virtual plane address

90 – 99

= 10 planes

X3)

= Slot number

1 – 4

for 2U units

1 – 6

for 3U units

1 – 8

for 4U units

1 – 10

for 5U units

00

= e-mail F & P

1 – 10

= e-mail I