4.4.14 Miscellaneous Menu (Level 2)

This menu covers the miscellaneous configuration items.

* Miscellaneous
0 Exit

1 Temperature [

C]

2 Initialize
3 WXT5x0 [No]

Option 1

This option defines the temperature scale in which the internal iRIS temperature will be displayed.

> Temperature Scale (0=

C, 1=F)=

Option 2

This option is used to initialise the unit. This is generally done just after installation as part of the
commissioning process to eliminate any test or residual data or totals. It resets the memory pointers to zero
and also resets all totalisers. To ensure this task is not accidentally invoked, a specific string must be typed
in order to execute the initialisation process.

> Type 'init' to initialize the unit

Option 3

This option is used to enable support for the Vaisala WXT5x0 Weather Transmitter. This device is a SDI-12
instrument with particular features that require special handling by the iRIS. Refer to Section 6.10 for more
information on connecting this instrument.

> Vaisala WXT5x0 connected? (0:No 1:Yes)=

4.4.15 Voice Menu (Level 2)

This menu, only available on the iRIS 320V and iRIS 350V, configures the voice annunciation feature.

* Voice Cfg
0 Exit
1 Mode [Cellular]
2 Sensors
>

Option 1

This option selects whether the voice access is via the cellular modem or via a special PSTN landline
adaptor. Contact iQuest for details on the availability and the use of this feature.

> Mode (0: Cellular, 1: Landline)=

Option 2

This list-based option enables which sensors will be included when a voice report is being played.

* Sensor Voice Enable
0 Exit
1 Sen1 [Yes]
. . .
9 Temp [No]
>

Selecting any of the sensor numbers (1-9) will display a prompt for enable or disable voice reporting for the
sensor. Enter 1 to include the chosen sensor in the voice report, or 0 to exclude it.

> Enable (0:No 1:Yes)=