4.4.2 Main Menu (Level 1)
The first menu displayed is the Main Menu. From here, you can make the following choices:
* iRIS 350V GPRS (AG1-0000 / F2.50 / S1.50)
1 Site Name [My Site Name]
2 Power [Full Save, Solar]
3 Comms
4 Sensors
5 Outputs
6 Date/Time [12 Jun 2009, 12:37:55, UTC +12hrs]
7 PIN Code [0001]
8 Miscellaneous
9 Voice
>
Option 1 - Site Name
Select this option to enter a name for the site that will be displayed on the main title screen of the LCD. The
maximum length of the site name is fixed at 19 characters. On the iRIS 320 this is 12 characters.
Option 2 - Power
When this option is selected you will be prompted to enter a number representing the power saving mode
required.
> Power Save (0:None 1:Partial 2:Full 3:RS232 only)=
Once the power save mode has been entered, you will then be prompted to enter the power source for the
charger (0 for fixed dc power supply or 1 for solar). This selects the battery charging profile the iRIS will use.
> Power Source (0:DC 1:Solar)=
Check the features section (Section 2.3.4) of this manual to learn more about the various power saving
modes available.
Option 3 - Comms
Select this option to display the Comms configuration menu.
Option 4 - Sensors
Select this option to display the Sensor configuration menu.
Option 5 - Outputs
Select this option to display the Digital Output configuration menu.
Option 6 – Date/Time
Select this option to display the Date/Time and clock configuration menu.
Option 7- PIN Code
When this option is selected you will be prompted to enter a security PIN code between 0 and 9999. This
PIN code is used to restrict access to specific LCD screens. If the PIN code is set to 0 (factory default) then
only the four status and the totaliser (view only) LCD screens are accessible.
> PIN Code=
Option 8 - Miscellaneous
Select this option to display the Miscellaneous configuration menu.
Option 9 – Voice or Camera
The Voice option is only available on the iRIS 3x0V models that are equipped for voice operation.
Select it to access the Voice configuration. See Appendix D – Voice Annunciation (iRIS 3x0V)
The Camera option is only available if the appropriate software variant is installed.
Select it to access the Camera configuration menu. See Appendix E - Using an iRIS-CAM Camera