Brown-out Detection

ATmega162 has an On-chip Brown-out Detection (BOD) circuit for monitoring the V

CC

level during operation by comparing it to a fixed trigger level. The trigger level for the
BOD can be selected by the BODLEVEL Fuses. The trigger level has a hysteresis to
ensure spike free Brown-out Detection. The hysteresis on the detection level should be
interpreted as V

BOT+

= V

BOT

+ V

HYST

/2 and V

BOT-

= V

BOT

- V

HYST

/2.

Notes:

1. V

BOT

may be below nominal minimum operating voltage for some devices. For

devices where this is the case, the device is tested down to V

CC

= V

BOT

during the

production test. This guarantees that a Brown-out Reset will occur before V

CC

drops

to a voltage where correct operation of the microcontroller is no longer guaranteed.
This test is performed using BODLEVEL = 110 for ATmega162V, BODLEVEL = 101
for ATmega162L, and BODLEVEL = 100 for ATmega162.

2. For ATmega162V. Otherwise reserved.

When the BOD is enabled and V

CC

decreases to a value below the trigger level (V

BOT-

in

Figure 25), the Brown-out Reset is immediately activated. When V

CC

increases above

the trigger level (V

BOT+

in Figure 25), the delay counter starts the MCU after the Time-

out period t

TOUT

has expired.

The BOD circuit will only detect a drop in V

CC

if the voltage stays below the trigger level

for longer than t

BOD

given in Table 18.

Table 19. BODLEVEL Fuse Coding

BODLEVEL Fuses [2:0]

Min. V

BOT

(1)

Typ. V

BOT

Max. V

BOT

Units

111

BOD Disabled

110

(2)

1.7

1.8

2.0

V

101

2.5

2.7

2.9

100

4.1

4.3

4.5

011

(2)

2.1

2.3

2.5

010

Reserved

001

000

Table 20. Brown-out Hysteresis

Symbol

Parameter

Min.

Typ.

Max.

Units

V

HYST

Brown-out Detector hysteresis

50

mV

t

BOD

Min Pulse Width on Brown-out Reset

2

µs