beautypg.com

Bert bit counter, 3 bert b, Ounter – Rainbow Electronics DS21458 User Manual

Page 193: 3 bert bit counter

background image

DS21455/DS21458 Quad T1/E1/J1 Transceivers

193 of 270

27.3 BERT Bit Counter

Once the BERT has achieved synchronization, this 32-bit counter will increment for each data bit (i.e.,
clock) received. Toggling the LC control bit in BC1 can clear this counter, which saturates when full and
will set the BBCO status bit.


Register Name:

BBC1

Register Description:

BERT Bit Count Register 1

Register Address:

E3h


Bit

# 7 6 5 4 3 2 1 0

Name BBC7 BBC6 BBC5 BBC4 BBC3 BBC2 BBC1 BBC0
Default

0 0 0 0 0 0 0 0


Bits 0 to 7/BERT Bit Counter Bits 0 to 7 (BBC0 to BBC7). BBC0 is the LSB of the 32-bit counter.

Register Name:

BBC2

Register Description:

BERT Bit Count Register 2

Register Address:

E4h


Bit

# 7 6 5 4 3 2 1 0

Name BBC15 BBC14 BBC13 BBC12 BBC11 BBC10 BBC9 BBC8
Default

0 0 0 0 0 0 0 0


Bits 0 to 7/BERT Bit Counter Bits 8 to 15 (BBC8 to BBC15).


Register Name:

BBC3

Register Description:

BERT Bit Count Register 3

Register Address:

E5h


Bit

# 7 6 5 4 3 2 1 0

Name BBC23 BBC22 BBC21 BBC20 BBC19 BBC18 BBC17 BBC16
Default

0 0 0 0 0 0 0 0


Bits 0 to 7/BERT Bit Counter Bits 16 to 23 (BBC16 to BBC23).


Register Name:

BBC4

Register Description:

BERT Bit Count Register 4

Register Address:

E6h


Bit

# 7 6 5 4 3 2 1 0

Name BBC31 BBC30 BBC29 BBC28 BBC27 BBC26 BBC25 BBC24
Default

0 0 0 0 0 0 0 0


Bits 0 to 7/BERT Bit Counter Bits 24 to 31 (BBC24 to BBC31). BBC31 is the MSB of the 32-bit counter.