beautypg.com

G1000 system message advisories, Appendix a, Mfd & pfd message advisories – Garmin G1000 Piper PA-46 Matrix User Manual

Page 551

background image

190-01108-00 Rev. B

Garmin G1000 Pilot’s Guide for the Piper PA-46 Mirage/Matrix

SY

STEM

O

VER
VIEW

FLIGHT

INSTRUMENTS

EICAS

AUDIO P

ANEL

& CNS

FLIGHT

MANA

GEMENT

HAZARD

AV

OID
ANCE

AFCS

ADDITIONAL

FEA
TURES

APPENDICES

INDEX

537

APPENDIX A

G1000 SYSTEM MESSAGE ADVISORIES

This section describes various G1000 system message advisories. Certain messages are issued due to an LRU

or an LRU function failure. Such messages are normally accompanied by a corresponding red ‘X’ annunciation
as shown previously in the G1000 System Annunciation section.

NOTE:

This Section provides information regarding G1000 message advisories that may be displayed by

the system. Knowledge of the aircraft, systems, flight conditions, and other existing operational priorities
must be considered when responding to a message. Always use sound pilot judgment. The POH takes
precedence over any conflicting guidance found in this section.

MFD & PFD MESSAGE ADVISORIES

Message

Comments

DATA LOST – Pilot stored data was
lost. Recheck settings.

The pilot profile data was lost. System reverts to default pilot profile and settings. The
pilot may reconfigure the MFD & PFDs with preferred settings, if desired.

XTALK ERROR – A flight display
crosstalk error has occurred.

The MFD and PFDs are not communicating with each other. The G1000 system should
be serviced.

PFD1 SERVICE – PFD1 needs service.
Return unit for repair.

The PFD and/or MFD self-test has detected a problem. The G1000 system should be
serviced.

PFD2 SERVICE – PFD2 needs service.
Return unit for repair.
MFD1 SERVICE – MFD1 needs
service. Return unit for repair.
MANIFEST – PFD1 software
mismatch, communication halted.

The PFD and/or MFD has incorrect software installed. The G1000 system should be
serviced.

MANIFEST – PFD2 software
mismatch, communication halted.
MANIFEST – MFD1 software
mismatch, communication halted.
PFD1 CONFIG – PFD1 config error.
Config service req’d.

The PFD configuration settings do not match backup configuration memory. The
G1000 system should be serviced.

PFD2 CONFIG – PFD2 config error.
Config service req’d.
MFD1 CONFIG – MFD1 config error.
Config service req’d.

The MFD configuration settings do not match backup configuration memory. The
G1000 system should be serviced.

SW MISMATCH – GDU software
version mismatch. Xtalk is off.

The MFD and PFDs have different software versions installed. The G1000 system
should be serviced.

PFD1 COOLING – PFD1 has poor
cooling. Reducing power usage.

The PFD and/or MFD is overheating and is reducing power consumption by dimming
the display. If problem persists, the G1000 system should be serviced.

PFD2 COOLING – PFD2 has poor
cooling. Reducing power usage.
MFD1 COOLING – MFD1 has poor
cooling. Reducing power usage.

This manual is related to the following products: