ZyXEL Communications Internet Security Gateway ZyWALL 100 User Manual
Page 58

ZyWALL 100 Internet Security Gateway
WAN Setup
5-5
FIELD
DESCRIPTION
DEFAULT
AT Response String:
CLID (Calling Line
Identification)
Enter the keyword that precedes the CLID (Calling Line Identification)
in the AT response string. This lets the ZyWALL capture the CLID in
the AT response string that comes from the WAN device. CLID is
required for CLID authentication.
NMBR =
Called Id Enter the keyword preceding the dialed number.
TO
Speed Enter the keyword preceding the connection speed.
CONNECT
Table 5-3 Advanced WAN Port Setup — Call Control Parameters
FIELD
DESCRIPTION
DEFAULT
Call Control
Dial Timeout (sec) Enter a number of seconds for the ZyWALL to keep trying to set up
an outgoing call before timing out (stopping). The ZyWALL times
out and stops if it cannot set up an outgoing call within the timeout
value.
60 seconds
Retry Count Enter a number of times for the ZyWALL to retry a busy or no-
answer phone number before blacklisting the number.
0 to disable
the blacklist
control
Retry Interval
(sec)
Enter a number of seconds for the ZyWALL to wait before trying
another call after a call has failed. This applies before a phone
number is blacklisted.
Drop Timeout
(sec)
Enter a number of seconds for the ZyWALL to wait before dropping
the DTR signal if it does not receive a positive disconnect
confirmation.
20 seconds
Call Back Delay
(sec)
Enter a number of seconds for the ZyWALL to wait between
dropping a callback request call and dialing the co-responding
callback call.
15 seconds