Serial Interface
13-26
13.3.3
Description of Registers for the Clock Synchronous Serial Interface
The clock synchronous serial interfaces include the registers listed in Table 13-3-1. These registers are used for
settings such as clock source selection, parity bit selection, and protocol selection.
Table 13-3-1 List of Clock Synchronous Serial Interface Registers
Address
Name
Symbol
Number of bits Initial value
Access size
x'34000810
Serial 1 control register
SC1CTR
16
x'0000
8, 16
x'34000814
Serial 1 interrupt mode register
SC1ICR
8
x'00
8
x'34000818
Serial 1 transmission buffer
SC1TXB
8
x'00
8
x'34000819
Serial 1 reception buffer
SC1RXB
8
x'00
8
x'3400081C Serial 1 status register
SC1STR
8
x'00
8
x'34000820
Serial 2 control register
SC2CTR
16
x'0000
8, 16
x'34000824
Serial 2 interrupt mode register
SC2ICR
8
x'00
8
x'34000828
Serial 2 transmission buffer
SC2TXB
8
x'00
8
x'34000829
Serial 2 reception buffer
SC2RXB
8
x'00
8
x'3400082C Serial 2 status register
SC2STR
8
x'00
8