Bus Controller (BC)
8-21
When using handshaking mode (Memory control register 3B
B3WM = 1)
Bit No.
Bit name
Description
Setting conditions
1
WM
Block 3 wait mode
1: Handshaking mode
2
BM
Block 3 bus mode
0: Synchronous mode (SYSCLK synchronization)
4
BW
Block 3 bus width
0:
8 bits
1:
16 bits
7 to 6
ASA1 to 0
AS assert timing
00:
0MCLK
11:
3MCLK
10 to 8
ASN2 to 0
AS negate timing
000:
prohibited
Set so that:
001:
1MCLK
ASN
≥
ASA
111:
7MCLK
15 to 11
WEN4 to 0
WE negate timing
00000:
0MCLK
11111:
31MCLK
~
~
~
~
~
~
Note: Handshaking mode can only be set when (MCLK frequency/SYSCLK frequency) = 4.
If (MCLK frequency/SYSCLK frequency) = 1 or 2, set B3WM = 0 in MEMCTR3B.
After the reset is released, block 3 is set as follows:
Address output end timing
3MCLK
RE negate timing
29MCLK
WE negate timing
29MCLK
RE/WE assert timing
3MCLK
Bus cycle start timing
0MCLK
Bus cycle end timing
31MCLK
AS assert timing
1MCLK
AS negate timing
3MCLK
The bus width is 16 bits, and synchronous fixed wait mode is set.