Printronix P5000LJ Series User Manual
Page 253
Set Commands
253
set user add|del username
set user add eng
Add or remove a user on the NIC defined by
username
.
set user passwd username password
set user passwd eng mplex1
Assign a
password
to a defined user on the NIC. This
password
must
be less than eleven characters.
set user type username root|guest
set user type eng root
Assign root or guest privileges to a particular user defined by
username
.
Guest permissions allow viewing of settings only. Root permissions allow
complete control of the NIC.
set user from default
Set all user settings back to factory defaults.
set user from stored
Set all current user settings to the values stored in flash memory.
set user passwd snmp com_name
Sets the new SNMP R/W community name as the
com_name
value.
set var variablename variablestring
set var LANDSCAPE 0x1b 0x26 0x6c 0x31 0x4f
set var FINISH $FF $PCL-RST
Define a new variable to be used in header, trailer, or switch strings on
the NIC and call it
variablename
.
variablestring
can be a space-
separated list of words, hexadecimal numbers
(e.g., 0x04), or references to other pre-defined variables. It is easiest to
make up the
variablestring
with hexadecimal values as shown in the
example.
One variable counts as one element within header and trailer strings.
Defined variables are referenced in strings by placing an
$
before the
variable name (e.g.,
set model m1 trailer $FF
).
set var from default
Set all variable settings back to factory defaults.
set var from stored
Set all current variable settings to the values stored in flash memory.
Note
Be careful not to delete the
root
user, or you will be unable to configure
any further settings on the print server. You will have to go back to factory
defaults to correct this problem.