3. Configuration
3-60
April
2002
9128-A2-GB20-60
Only those DSX-1-to-Network assignments from page 1 are displayed on this
page, from left to right and top to bottom in ascending order, by network and time
slot.
When a CGA condition (LOS, OOF, or AIS) is declared for a T1 interface, the
signaling bits being transmitted to the other T1 interface for the DS0 are forced to
idle for two seconds (except for user-defined patterns which are transmitted
immediately). This drops any call in progress. The signaling bits are then forced to
the selected state (Busy or Idle), and remain in this state until the CGA condition
clears. At this point, the received signaling bits from the T1 interface which
formerly had the CGA condition are passed through to the other T1 interface.
NOTE:
Trunk conditioning will only occur on DS0s that are cross-connected to
another T1 interface. All other DS0s remain unaffected by trunk conditioning.
Enter one of the values shown in
Table 3-12, Signaling and Trunk Conditioning
, in each of the fields on both the Network side and the DSX-1 side.
Although you can choose any value for the DSX-1 side, the default value displayed
is based on a typical setting that would be used with the corresponding Network
side value. Typical pairs of values are shown in the table below. If you change the
Network side value, the DSX side value is changed to the corresponding default
value.
Table 3-12. Signaling and Trunk Conditioning Values (1 of 3)
Network Side
Meanings
DSX-1 Side
None
No signaling used on this DS0. Use this setting if
there is no voice signaling information being passed
on this DS0 (clear channel).
None
RBS (default)
Robbed Bit Signaling is used on this DS0, but no
trunk conditioning. Signaling bits will be passed to the
T1 interface to which this DS0 is cross-connected
when this T1 interface is not in CGA, but the signaling
bits will be all ones when CGA is present.
RBS
The following values configure the cross-connect for RBS, as well as perform the
trunk conditioning. Although ABCD signaling bits for each setting are described,
only AB bits are transmitted when the cross-connected T1 network interface is
using D4 framing.