Paradyne 9128-II User Manual
Page 247
6. Troubleshooting
9128-A2-GB20-60
April 2002
6-11
OOF at Network 1
An Out of Frame (OOF)
condition is detected on the
network interface.
T
Incompatible framing
format between the
network and the
FrameSaver unit.
T
Network cabling
problem.
T
T1 facility problem.
T
Check that the framing format
for the network interface is
correct.
T
Check that the network cable is
securely attached at both ends.
T
Contact your network provider.
Power Supply/Fan
Alarm
The power supply output
voltage has dropped below
the specified tolerance level
required for the system. Or
one or both fan trays are not
operating properly.
Check the LEDs on the power
supply and fan trays to determine
which may have failed, then
replace the failed component.
Primary Clock Failed
A failure of the configured
primary clock source for the
unit was detected and the
secondary clock is
providing the timing for the
unit.
This condition clears when
the configured primary
clock is restored.
T
Check that the network cable is
securely attached at both ends.
T
Contact your network provider.
Primary & Secondary
Clocks Failed
A failure of both clock
sources configured for the
unit was detected.
This condition only applies
to T1 network and DSX-1
interfaces. It clears when
the configured primary
clock is restored.
Secondary Clock
Failed
A failure of the configured
secondary clock source for
the unit was detected and
the internal clock is
providing the timing for the
unit.
The clock source will not
automatically switch from
internal until the primary
clock source returns.
Table 6-1.
Alarm Conditions (5 of 7)
Alarm Condition
What It Indicates
What To Do
1
nnnn
indicates a DLCI number of 16 through 1007.
2
frame relay link
is one of the following:
– Net1-FR1. The frame relay link specified for the network interface, Network 1.
– Port-
n
. The frame relay link associated with a user data port.
–
ISDN Link Name
on a non-network ISDN DBM interface.
3
Does not apply to a TS Access Management Link DLCI.