Table 5-2, network, dsx, or pri interface leds, Table 5-3, user data port led – Paradyne 9128-II User Manual
Page 166
5. Operation and Maintenance
5-10
April
2002
9128-A2-GB20-60
Table 5-2.
Network, DSX, or PRI Interface LEDs
Label
Indication
Color
What It Means
SIG Signal
Green
ON
– A recoverable signal is present on the
Network/DSX/PRI interface.
OFF – The signal cannot be recovered from the
Network/DSX/PRI interface. An LOS condition
exists.
OOF
Out of Frame
Yellow
ON – At least one OOF was detected during the
sampling period.
OFF – No OOFs were detected during the
sampling period.
ALM
Alarm
Yellow
ON – An alarm condition is present on the
network/DSX/PRI interface.
Current alarm conditions:
T
Loss of Signal ( LOS)
T
Loss of Frame (LOF)
T
Out of Frame (OOF)
T
Excessive Error Rate (EER)
T
Yellow Alarm Signal
T
Alarm Indication Signal (AIS)
OFF – No alarm condition is present on the
Network/DSX/PRI interface.
Table 5-3.
User Data Port LED
Label
Indication
Color
What It Means
OK
1
Operational
Status
Green
ON – The interchange circuits for the port are in
the correct state to transmit and receive data.
OFF – The port is idle. Occurs if the port is
disabled, or if the port is configured to monitor
DTR and/or RTS and the lead(s) is not asserted.
1
The FrameSaver SLV 9128-II only has one OK LED even though it has two user
data ports. If either port is enabled and active, the LED is on. If both ports are
enabled and one of the ports is inactive, the LED is off.