Send pattern, Monitor pattern – Paradyne 9128-II User Manual
Page 260
6. Troubleshooting
6-24
April
2002
9128-A2-GB20-60
Send Pattern
This test sends packets filled with a hexadecimal 55 test pattern and sequence
number over the selected interface and DLCI to another FrameSaver device.
To send a pattern test on a link:
Main Menu
→
Test
→
[Network PVC Tests/Data Port PVC Tests/
ISDN Call/PVC Tests]
If the CIR is zero, the pattern will be sent at a rate of 1000 bps.
Monitor Pattern
This test monitors packets filled with a hexadecimal 55 test pattern and sequence
number over the selected interface and DLCI to another FrameSaver device.
To monitor a pattern test on a link:
Main Menu
→
Test
→
[Network PVC Tests/Data Port PVC Tests/
ISDN Call/PVC Tests]
The current number of sequence and data errors are shown under the Result
column when the
FrameSaver unit is in sync. An
Out of Sync
message appears
when 5 frames out of 25 are missing or out of sequence.
These error counts are updated every second. If the maximum count is reached,
99999+
appears in these fields.
If the selected DLCI is
configured as . . .
Then . . .
And the default
Rate (Kbps) setting is . . .
Standard
(Disruptive)
appears
after Test
100% of CIR
Multiplexed
(Non-Disruptive)
appears after Test
10% of CIR