Configuring snmp traps and trap dial-out, Table 3-22, snmp traps and trap dial-out options – Paradyne 9128-II User Manual
Page 125
3. Configuration
9128-A2-GB20-60
April 2002
3-91
Configuring SNMP Traps and Trap Dial-Out
Select SNMP Traps from the Management and Communication menu to configure
SNMP traps and dial-out when a trap is generated (see
).
Main Menu
→
Configuration
→
Management and Communication
→
SNMP
Traps
See
SNMP MIBs and Traps, and RMON Alarm Defaults
, for trap
format standards and special trap features, including RMON-specific traps, and
the default settings that will generate RMON-specific SNMP traps.
Access Type
Possible Settings: Read, Read/Write
Default Setting: Read
Specifies the type of access allowed for an authorized NMS when IP address validation is
performed.
Display Conditions
– This option appears for each trap manager specified in the
Number of Trap Managers configuration option.
Read – Allows read-only access (SNMP Get command) to the MIB objects. This includes
all objects specified as either read-only or read/write in the MIB RFCs.
Read/Write – Allows read and write access (SNMP Get and Set commands) to the MIB
objects. However, access for all read-only objects is specified as read-only.
Table 3-21. SNMP NMS Security Options (2 of 2)
Table 3-22. SNMP Traps and Trap Dial-Out Options (1 of 6)
SNMP Traps
Possible Settings: Enable, Disable
Default Setting: Disable
Determines whether the FrameSaver unit sends trap messages to the currently
configured SNMP trap manager(s).
Enable – Sends trap messages.
Disable – Does not send trap messages.
Number of Trap Managers
Possible Settings: 1 – 6
Default Setting: 1
Specifies the number of SNMP management systems that will receive SNMP trap
messages from the FrameSaver unit. An NMS IP Address must be configured in the NMS
n
IP Address configuration option for each trap manager to receive trap messages.
1 – 6 – Specifies the number of trap managers (inclusive).