Configuring Service

Level Verification Options

SLV options are selected from the System menu (see

Table 3-4, Service Level

Verification Options

).

Main Menu

Configuration

System

Service Level Verification

Table 3-4.

Service Level Verification Options (1 of 3)

SLV Sample Interval (secs)

Possible Settings: 10 – 3600
Default Setting: 60

Sets the inband communications interval between FrameSaver SLV devices. Inband
communications are used to pass frames that calculate latency, as well as transmission
success and other SLV information.

10 – 3600 – Sets the SLV Sample Interval (secs) in seconds.

SLV Synchronization Role

Available Settings: Tributary, Controller, None
Default Setting: Tributary

Determines the role the unit plays in maintaining synchronization of user history data
collection and storage between FrameSaver SLV and/or FLEX devices.

Tributary – Uses network timing received from incoming SLV communications and
provides network-based synchronization information to other devices in the network.

Controller – Uses its own internal time-of-day clock and provides synchronization
information to other devices in the network based upon its own clock.

NOTE: Only one device in the network should be configured as the SLV
synchronization controller.

None – Incoming timing information is ignored and no timing information is sent out. This
setting should only be used when network synchronization is not desirable, or when a
single unit connects multiple networks or network segments.

SLV Type

Available Settings: Standard, COS 1–COS 7
Default Setting:

If SLV Feature is enabled:

Standard

If SLV Feature is disabled:

COS 1

Determines the type of SLV measurements to which these other SLV options apply:

T

SLV Timeout Error Event Threshold

T

SLV Timeout Clearing Event Threshold

T

SLV Round Trip Latency Error Threshold

T

SLV Latency Clearing Event Threshold

T

SLV Packet Size

Standard – The options selected apply to standard FrameSaver SLV measurements,
utlizing an EDLCI for FrameSaver-to-FrameSaver communication. This option is not
available if the SLV Feature is disabed.

COS 1–COS 7 – The options selected apply to this Class of Service. Different settings
may be saved for each Class of Service.