Setting up dial backup, Setting up the dbm physical interface – Paradyne 9128-II User Manual
Page 51
3. Configuration
9128-A2-GB20-60
April 2002
3-17
Setting Up Dial Backup
When configuring units with ISDN backup capability, the following guidelines
apply:
T
Central site configuration guidelines:
— Set up the ISDN DBM physical interface.
— If a BRI DBM, change the Automatic Backup Configuration to
Multi_Site_Backup. (A PRI DBM is already configured for multisite
backup.)
— Modify the Link Profile(s) that Automatic Backup Configuration created to
add a phone number.
T
Remote site configuration guidelines:
— Set up the ISDN DBM physical interface.
— If a PRI DBM, change the Automatic Backup Configuration to
Single_Site_Backup. (A BRI DBM is already configured for single-site
backup.)
— Modify the HQ_Site Link Profile that Automatic Backup Configuration
created to add a phone number.
— Set the criteria by which automatic backup will take place.
Setting Up the DBM Physical Interface
Procedure
1. Configure the DBM interface.
Main Menu
→
Configuration
→
ISDN
→
Physical
2. Enable the interface, and enter the Service Profile IDs (SPIDs) and local
phone numbers.
3. Save the configuration.
See
Table 3-9, ISDN BRI DBM Physical Interface Options
, or
PRI DBM Physical Interface Options
, for configuration information.