DLCI Performance Statistics

These statistics appear when DLCI is selected from the Performance Statistics
menu.

Main Menu

Status

Performance Statistics

DLCI

Table 5-17. DLCI Performance Statistics (1 of 2)

Statistic

What It Indicates

DLCI Up Since *

Date and time that the DLCI was last declared Active after a
period of inactivity. Down is displayed if the DLCI is inactive.

If the DLCI was Down, this is the time that the DLCI recovered.

If the DLCI was never Down, this is the first time the unit
discovered that the DLCI was active in the network.

DLCI Up Time *

Days, hours, minutes, and seconds since the DLCI was last
declared Active after a period of inactivity. Down is displayed if
the DLCI is inactive.

If the DLCI was Down, this is the amount of time since the DLCI
recovered.

If the DLCI was never Down, this is the amount of time since the
unit discovered that the DLCI was active in the network.

Total Tx Frames/
Tx Octets

Total number of data frames and octets ( 8-bit bytes) transmitted
for the selected DLCI on the frame relay link.

T

Within CIR

T

The number of frames and octets sent by the far-end device
for on the selected DLCI of the frame relay link that were
within the committed information rate.

T

Between CIR&EIR

T

The number of frames and octets sent by the far-end device
on the selected DLCI of the frame relay link that were
between the committed information rate and excess
information rate.

T

Above EIR

T

The number of frames and octets sent by the far-end device
on the selected DLCI of the frame relay link that were above
the excess information rate.

T

With DE Set

T

The number of frames and octets sent on the selected DLCI
of the frame relay link with the discard eligible bit set.

Total Tx Frames/
Tx Octets

T

With BECN Set

T

The number of frames and octets sent on the selected DLCI
of the frame relay link with backward explicit congestion
notifications.

BECNs are sent to notify users of data traffic congestion in
the opposite direction of the frame carrying the BECN
indicator.

Total Rx Frames/
Rx Octets

Total number of data frames and octets ( 8-bit bytes) received for
the selected DLCI on the frame relay link.

T

Within CIR

T

The number of frames and octets received on the selected
DLCI of the frame relay link that were within the committed
information rate.

* Only appears for the network interface.