beautypg.com

Paradyne 9128-II User Manual

Page 245

background image

6. Troubleshooting

9128-A2-GB20-60

April 2002

6-9

LMI Down,

frame relay

link

2

The Local Management
Interface is down for the
specified frame relay link.

For the network interface:

T

If LMI was never up, verify that
the LMI Protocol setting
reflects the LMI type being
used.

T

If LMI was never up:

– Verify that the proper time

slots have been configured.

– Verify that the LMI Protocol

setting reflects the LMI type
being used.

T

Verify that Frame Relay
Performance Statistics show
LMI frames being transmitted.

If all of the above have been
verified and the physical link is not
in Alarm, contact your network
provider.

For user data port:

T

Check that the DTE cable is
securely attached at both ends.

T

Verify that Transmit Clock
Source and Invert Transmit
Clock options are properly
configured.

T

Verify that Frame Relay
Performance Statistics show
LMI frames being received. If
no frames are being received:

– Check the attached device.

– Verify that the LMI Protocol

setting reflects the LMI type
being used.

Table 6-1.

Alarm Conditions (3 of 7)

Alarm Condition

What It Indicates

What To Do

1

nnnn

indicates a DLCI number of 16 through 1007.

2

frame relay link

is one of the following:

– Net1-FR1. The frame relay link specified for the network interface, Network 1.
– Port-

n

. The frame relay link associated with a user data port.

ISDN Link Name

on a non-network ISDN DBM interface.

3

Does not apply to a TS Access Management Link DLCI.

This manual is related to the following products: