Paradyne 9128-II User Manual
Page 184
5. Operation and Maintenance
5-28
April
2002
9128-A2-GB20-60
Monitor
Pttn
Active,
Interface
2
A Monitor Pattern test is active on the specified
interface.
This test cannot be activated on user data ports that
have Port Use set to Frame Relay.
Network Initiated ISDN BRI Test
Active
An ISDN test has been started by the ISDN BRI
network and it is currently active.
Send
Pttn
Active, DLCI
nnnn
,
frame_relay_link
1 ,3
A selected Send Pattern test is active on the
specified DLCI for the specified frame relay link.
Monitor
Pttn
Active, DLCI
nnnn
,
frame_relay_link
1 ,3
A selected Monitor Pattern test is active on the
specified DLCI for the specified frame relay link.
Test Call Active,
ISDN Link Name
A test call is active on the specified frame relay link,
the link being the ISDN Link Name assigned in the
ISDN Link Profile.
This message would only appear for units with the
ISDN DBM feature.
Table 5-8.
Test Status Messages (2 of 2)
Message
What It Indicates
1
frame relay link
is one of the following:
– Net1-FR1. The frame relay link specified for the network interface, Network 1.
– Port-
n
for a 1-slot unit, or S
s
Port-
n
for a NAM in a multislot housing (the frame relay
link associated with the specified user data port in the specified slot).
–
ISDN Link Name
on a non-network ISDN DBM interface.
2
Interface
is one of the following:
– Network 1
– DSX-1
– Port-
n
– ISDN, BRI or PRI
3
nnnn
indicates a DLCI number of 16 through 1007.