5. Operation and Maintenance

5-72

April

2002

9128-A2-GB20-60

Placing a Test Call (Nondisruptive)

Use this procedure to test the ISDN path to each remote site. This procedure will
not put the system into backup.

Procedure

1. Make sure the ISDN Link Profiles and DLCIs are set up correctly for the DBMs

at each end (see

Modifying ISDN Link Profiles

in Chapter 3,

Configuration.

Main Menu

Configuration

ISDN

Link Profiles

Main Menu

Configuration

ISDN

DLCI Records

2. Place a Test Call from one of the devices.

Main Menu

Test

ISDN Call/PVC Tests

— Select the link to be tested.

— Start a Test Call. The Status should be Active.

— Select Stop to end the Test Call.

Use this procedure to test the ISDN path to each remote site. This procedure will
not put the unit into backup.

If the Result is . . .

Then . . .

Frame Relay Link Up

The call was successful.

Frame Relay Link Down

The call was not successful. Verify the configuration and
Link Status in the ISDN Link Profile.