beautypg.com

Manually configuring dlci records, R to, Table 4-14, dlci record options – Paradyne CSU User Manual

Page 108

background image

4. Configuration Options

4-64

September

2002

9128-A2-GB20-80

Manually Configuring DLCI Records

The Auto-Configuration feature automatically configures DLCI Records and their
PVC Connections. DLCI Records can also be created manually (see

Table 4-14,

DLCI Record Options

).

Main Menu

Configuration

[Network/Data Port/ISDN/Virtual Router Ports]

DLCI Records

Available paths to DLCI Records Options depend on the FrameSaver model:

T

Data Port is available only on CSU/DSUs

T

ISDN is available only when the FrameSaver unit has an ISDN DBM installed

T

Virtual Router Ports is available only on the FrameSaver SLV Router

Typically, DLCI Records only need to be configured when building Management
PVCs between the NOC and the central site unit; the unit automatically configures
non-management DLCI Records and PVC Connections.

Table 4-14. DLCI Record Options (1 of 4)

DLCI Number

Possible Settings: 16 – 1007
Default Setting: Initially blank; no default.

Specifies the number for the DLCI in the DLCI record. The parameter determines which
DLCI record is used for transferring data on a particular frame relay interface. DLCI
numbers range from 0 to 1023. However, the numbers 0 – 15 and 1008 – 1023 are
reserved. Entry of an invalid number results in the error message

Value Out of Range

(16 – 1007)

. If the DLCI number is part of a connection, this field is read-only.

NOTES:

– If a DLCI number is not entered, the DLCI record is not created.

– The DLCI number entered must be unique for the interface.

– Changing settings for this configuration option causes the FrameSaver unit to abort

any active frame relay tests.

16 – 1007 – Specifies the DLCI number (inclusive).

This manual is related to the following products: