beautypg.com

Device messages – Paradyne CSU User Manual

Page 194

background image

7. Operation and Maintenance

7-12

September

2002

9128-A2-GB20-80

Device Messages

These messages appear in the messages area at the bottom of the screens. All
device messages are listed in alphabetical order.

Table 7-6.

Device Messages (1 of 6)

Message

What It Indicates

What To Do

Access level is

n

,

Read-only.

User’s access level is 2 or
3; user is not authorized to
change configurations.

No action needed.

Already Active

Test selected is already
running.

T

Allow test to continue.

T

Select another test.

T

Stop the test.

Blank Entries
Removed

New had been selected
from the Administer Logins
screen, no entry was made,
then Save was selected.

T

No action needed.

T

Reenter the Login ID,
Password, and Access Level.

Cannot Delete Trap
Manager

Del ete was selected from
the Management PVCs
Options screen, but the
PVC had been defined as a
trap destination.

No action needed, or configure
another path for traps and try
again.

Cannot Save – no
Level 1 Login IDs

Security was being set up,
but all the logins were
assigned either Level-2 or
Level-3 access.

Set up at least one login with
Access Level-1 so the unit can be
configured.

Command Complete

Configuration has been
saved or all tests have been
aborted.

No action needed.

Connection Refused

(Seen at an FTP
terminal.)

Two menu-driven user
interface sessions are
already in use when a
Telnet session was
attempted.

Wait and try again.

Destination Not
Unique

Destination entered is
already being used.

Enter another destination
indicator.

DLCI in connection.
Delete connection first

User tried to delete a DLCI
that was part of a
connection.

T

No action needed, or

T

Delete the connection, then
delete the DLCI.

DLCI Number Already
Exists

The DLCI number entered
on the DLCI Record Entry
screen has already been
created so is not unique.

Enter another DLCI number.

DLCI Number
Reserved

User tried to designate a
special troubleshooting
DLCI.

No action is needed.

This manual is related to the following products: