Paradyne CSU User Manual
Page 198
7. Operation and Maintenance
7-16
September
2002
9128-A2-GB20-80
Please Wait
Command takes longer
than 5 seconds.
Wait until message clears.
Port Inactive
(FrameSaver SLV
9128-II only)
The port is disabled, or it
supports synchronous data
when a DTE Loopback was
started.
No action is needed.
Resetting Device,
Please Wait ...
Yes (or y) was entered in
the
Reset COM Port usage
field of the System Paused
menu.
No action needed.
Save Cancelled
(FrameSaver SLV
9128-II only)
Changes were made on the
Easy Install screen, but
when it came to saving the
changes, the Esc key was
pressed or No was entered
in response to the
Save
Changes?
prompt.
No action is needed.
Test Active
No higher priority System
and Test Status messages
exist, and a test is running.
T
Contact service provider if test
initiated by the network.
T
Wait until the test ends and
message clears.
T
Cancel all tests from the Test
screen ( Path: main/test).
T
Stop the test from the same
screen the test was started
from.
User Interface Already
in Use
Two Telnet sessions are
already in use when an
attempt to access the
menu-driven user interface
through the COM port is
made.
IP addresses and logins of
the users currently
accessing the interface are
also provided.
T
Wait and try again.
T
Contact one of the IP address
user and request that they log
off.
User Interface Idle
Previously active session is
now closed/ended, and
access via the COM port is
now available.
Log on to the FrameSaver unit.
Session has been ended
due to timeout.
No action needed.
Table 7-6.
Device Messages (5 of 6)
Message
What It Indicates
What To Do